Key Inputs
Air Sealing Logic Engine
| Strategy & Logic | Strategy-specific Inputs | ΔCFM50 - leakage reduced | % leakage reduced | Projected Unit Compartmentalization (ACH50) | Projected Whole-Building Infiltration (ACH50) |
|---|---|---|---|---|---|
AS-01 i Seal box beams to sleepers Sill plates are the longest continuous junction in the shell. By sealing this line, you are neutralizing hundreds of feet of potential leakage in one shot. Source: PNNL: Sealing Sill Plates | i ft i in | 108.00 | 14.71% | 3.04 | 1.52 |
AS-02 i Foam mating wall gaps Voids between modules act as unconditioned zones so sealing them will eliminate the highest shared air situation. Source: BSC: Sealing the Right Walls | i fraction | 363.52 | 49.50% | 1.80 | 0.90 |
AS-03 i Seal mechanical chases Height drives the straw effect as noted in the report. Source: BSC: Sealing Penetrations | i sq ft i ft i F i ratio i R i ft/s² | 285.37 | 38.86% | 2.18 | 1.09 |
AS-04 i Stairwell drywall strip & sealant Bridges the RC gap around unit boundaries. Source: DOE: Multifamily Separation Walls | i ft i in | 337.50 | 45.96% | 1.93 | 0.96 |
AS-05 i Seal accessible MEP penetrations Air seal around all plumbing and piping installed through walls, ceilings, and flooring. Source: ES MFNC Field Checklist | i ft i in | 270.00 | 36.77% | 2.25 | 1.13 |
AS-06 i Tape all subfloor seams We need to choose the primary pressure plane preventing air entry into floor cavities. Source: DOE: Air Seal Subfloor Penetrations | i ft i in | 2235.60 | 304.42% | 0.00 | 0.00 |
AS-07 Seal Zip sheathing at bottom Required to connect Zip to foundation sleepers. Source: PHIUS basics | Coming Soon | --- | --- | --- | --- |
AS-08 Sealant beads at sleepers Replaces structural gaps with high performance gasket seal during box set. Source: PNNL: Modular Marriage Joints | Coming Soon | --- | --- | --- | --- |
AS-09 i Sealant at rim joist perimeter Rim joists typically account for 15-25% of total envelope infiltration. Source: BSC: Air Barrier Research | i ft i fraction | 110.16 | 15.00% | 3.03 | 1.52 |
AS-10 i Seal register boots High pressure duct to wall cavity bypass leakage prevention. Source: PNNL: Sealing Drywall to Plate | i count i sq in | 162.00 | 22.06% | 2.78 | 1.39 |
AS-11 Air seal bottom plates This should address baseboard-to-floor bypasses found during Gilman testing. Source: PNNL: Air Sealing Plumbing | Coming Soon | --- | --- | --- | --- |
AS-12 i Seal rim joist before Zip Pre-sheathing ensures continuity in field or factory. Source: Siplast: Air Barrier Transitions | i fraction | 110.16 | 15.00% | 3.03 | 1.52 |
AS-13 Seal beam before Zip Sealant bead isolates structural frame from exterior sheathing as per ASHRAE 90.1. Source: PNNL: Modular Marriage Joints | Coming Soon | --- | --- | --- | --- |